Commit Graph
2 Commits
Author SHA1 Message Date
hamedandClaude Opus 5 a63de2a52c fix(treatment): let the operator actually record an area
Starting a session created area records with no device, and the panel only ever
read the device it never set — so every "اتمام این ناحیه" came back 422 with
"دستگاه این ناحیه مشخص نیست". The backend tests passed because they sent
resource_uuid explicitly; from the UI the flow was unusable end to end.

The device now inherits from the appointment's resource, which the secretary
already chose at booking; asking the operator again is taking one decision
twice. The session screen offers a picker per area on top of that, because one
session really does run bikini on an alexandrite and underarms on a diode.

Treating without a device is allowed: botox is an injection, and requiring a
device would make clinics invent a fake resource per injection. Sending readings
with no device is still rejected — there would be no schema to validate against.

A protocol whose service has no ResourceServiceOffering rows now says so in the
tab where the manager is standing. It does not block booking: "no offering means
any resource" is a deliberate, tested rule. But silence meant the gap surfaced
only when the operator was already in front of a patient.

Also adds the live timer the spec asked for, and wires slot-suggestions into the
unbooked queue — the endpoint existed and tested green but no screen called it.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-08-07 11:08:48 +03:30
hamedandClaude Opus 5 d8aabe5d0a feat(admin): treatment plan tab, staff session screens and the device form editor
Three screens, each reusing what already exists rather than inventing a parallel
look. The treatment plan lives as a tab on the service page next to categories,
because the course belongs to the service; the switch is the protocol's existence
rather than a separate boolean that could disagree with the step list. Each step
asks for days since the previous session, which is how the interval actually
works and what the form should therefore say.

The staff screens are the flow from the reference screenshots: today's sessions,
then a session where each area is started, recorded and closed on its own. Field
inputs are built from the schema the server sends per resource type, so a clinic
adding an RF device sees its own form here without a code change.

StatusBadge gains treatment session and area states rather than a second badge
component sitting beside it, and the resource type modal grows a field editor so
the operator form is configured where the device is defined.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-08-06 18:29:49 +03:30